All articles

Bolted Connection Design: AISC 360 Guide

Updated Jul 8, 202613 min read
#AISC 360#bolted-connection#slip-critical#high-strength-bolts#block-shear#bearing-strength
Bolted Connection Design: AISC 360 Guide

Master bolted steel connection design: bolt grades, shear and bearing checks, tearout, block shear, and slip-critical vs bearing-type connections per AISC 360-22.

Key takeaways

  • Design is a hunt for the governing limit state: bolt shear, bearing, tearout, block shear, net section, or, for axial bolts, tension and prying action.
  • Block shear often governs short or coped connections: in the worked example it beat both bolt shear and tearout.
  • Slip-critical capacity is roughly half the bearing-type shear value, so those joints need more bolts or Class B faying surfaces.
  • Bolts in tension must be checked for prying: the bolt resists T + Q, and a thin flange can fail a joint the pure-tension check passed.
  • Combined shear and tension is not additive: AISC J3.7 reduces the available tensile stress F′_nt in proportion to the shear present.
A university student? With an academic email (.edu, .ac.uk…) CalcSteel is free for you.

What is a bolted connection in steel structures?

A bolted connection transfers forces between steel members using high-strength bolts passing through aligned holes. It is the most common connection type in steel construction because bolts are fast to install, allow field adjustments, and can be inspected visually.

Every bolted connection must be designed so that no single failure mode — bolt shear, bearing, tearout, block shear, or net section rupture — is exceeded under factored loads. AISC 360-22 Chapter J provides the limit-state equations, and the designer's job is to identify the governing mode. Whether the joint must carry moment or only shear reshapes the entire bolt layout — see moment vs shear connections.

Bolted connections fall into two categories:

  • Bearing-type: Bolts transfer load through direct shear and bearing against the plate. Slip is allowed. This is the default for most connections.
  • Slip-critical: Bolts are pretensioned to clamp the plies together, and load is transferred by friction. Required when slip would cause misalignment, fatigue issues, or when oversized/slotted holes are used.
Close-up photograph of a bolted steel connection with high-strength bolts joining two plates through aligned holes
A field-bolted steel connection: high-strength bolts transfer load through aligned holes. Photo: Unsplash (free license).

What bolt grades are used in structural steel connections?

Structural bolts are high-strength fasteners, not ordinary machine bolts. The two primary grades are:

ASTM A325 (equivalent: ISO 8.8, ASTM F3125 Gr F1852)

  • Ultimate tensile strength: F_ut = 830 MPa (120 ksi)
  • Nominal shear strength (threads excluded): F_nv = 457 MPa
  • Nominal tensile strength: F_nt = 620 MPa
  • Available in diameters M16 to M36
  • Most common bolt in US structural practice

ASTM A490 (equivalent: ISO 10.9, ASTM F3125 Gr F2280)

  • Ultimate tensile strength: F_ut = 1040 MPa (150 ksi)
  • Nominal shear strength (threads excluded): F_nv = 579 MPa
  • Nominal tensile strength: F_nt = 780 MPa
  • Used when A325 bolts are insufficient or fewer bolts are desired
  • Not permitted for galvanized connections (hydrogen embrittlement risk)

The -N suffix means threads are in the shear plane (reduces shear capacity to 80% of the -X value). Always specify -N unless you can guarantee threads are excluded from the shear plane, which is difficult in practice.

> CalcSteel tip: The connection editor automatically selects bolt grade and diameter based on demand forces, and checks every failure mode in one pass.

Table of bolt grades A307, A325 and A490 with tensile, shear and tension design stresses (Fut, Fnv, Fnt) and typical use cases
Nominal ultimate, shear and tensile strengths (F_ut, F_nv, F_nt) for A307, A325 and A490 structural bolt grades.

How do you check bolt shear strength per AISC 360?

Bolt shear is usually the first check. The design shear strength per bolt is:

φR_n = φ × F_nv × A_b

Where:

  • φ = 0.75 (LRFD) or Ω = 2.00 (ASD)
  • F_nv = nominal shear stress (depends on grade and thread condition)
  • A_b = nominal bolt area = π d² / 4

Worked example — 3×M20 A325-N bolts in single shear

  • d = 20 mm → A_b = π(20)²/4 = 314.2 mm²
  • F_nv = 457 MPa (A325, threads in shear plane → use F_nv directly per AISC Table J3.2)
  • Per bolt: φR_n = 0.75 × 457 × 314.2 × 10⁻³ = 107.7 kN
  • For 3 bolts: φR_n_total = 3 × 107.7 = 323 kN

If the factored load P_u ≤ 323 kN, the bolts pass in shear.

For double shear (bolts passing through three plies), the capacity doubles because each bolt has two shear planes.

Thread condition matters

A325-N (threads included): F_nv = 457 MPa A325-X (threads excluded): F_nv = 579 MPa

The -X condition gives 27% more capacity, but you must install the bolt so the thread length does not extend into the shear plane. This is reliably achievable only with careful detailing and bolt length selection.

Steel frame structure under construction showing multiple bolted beam-to-column connections
Every bolted joint in a steel frame must clear the shear check before any other limit state. Photo: Unsplash (free license).

How do you check bearing and tearout strength at bolt holes?

Even if the bolts are strong enough, the plate around the holes can fail by bearing deformation or tearout between the hole and the edge.

Bearing strength (AISC J3.10)

φR_n = φ × 2.4 × d × t × F_u

Where d = bolt diameter, t = plate thickness, F_u = plate ultimate strength.

For M20 bolt, 10 mm plate (F_u = 400 MPa): φR_n = 0.75 × 2.4 × 20 × 10 × 400 × 10⁻³ = 144 kN per bolt

Tearout strength (AISC J3.10)

φR_n = φ × 1.2 × L_c × t × F_u

Where L_c = clear distance from bolt hole edge to the nearest edge or adjacent hole.

For the end bolt with edge distance = 30 mm and hole diameter = 22 mm: L_c = 30 − 22/2 = 30 − 11 = 19 mm φR_n = 0.75 × 1.2 × 19 × 10 × 400 × 10⁻³ = 68.4 kN

For interior bolts with spacing = 60 mm: L_c = 60 − 22 = 38 mm φR_n = 0.75 × 1.2 × 38 × 10 × 400 × 10⁻³ = 136.8 kN

The total connection capacity is the sum of the governing value (min of bearing and tearout) at each bolt.

Total = 68.4 + 136.8 + 136.8 = 342 kN

Notice the end bolt's tearout capacity (68.4 kN) is much less than the interior bolts (136.8 kN). Increasing the edge distance to 40 mm would raise the end bolt tearout to 87 kN — a 27% improvement for no extra material.

Bar chart comparing design capacities of bolt shear, plate bearing, tearout, block shear and net section for a 3-bolt M20 A325 connection
Design capacity of each limit state for the 3-bolt M20 A325 example — the shortest bar (block shear) governs.

What is block shear failure in a bolted connection?

Block shear occurs when a block of material tears out of the connected plate along a combination of shear and tension planes. It is critical for coped beams, gusset plates, and short connections.

The AISC equation (J4.3) is:

φR_n = φ × (0.6 × F_u × A_nv + U_bs × F_u × A_nt) ≤ φ × (0.6 × F_y × A_gv + U_bs × F_u × A_nt)

Where:

  • A_nv = net area along the shear plane(s)
  • A_nt = net area along the tension plane
  • A_gv = gross area along the shear plane(s)
  • U_bs = 1.0 for uniform tension, 0.5 for non-uniform tension
  • φ = 0.75

Checking block shear for our example

3 bolts in a single vertical line, 10 mm plate, edge distance 30 mm, spacing 60 mm:

Shear plane (along the bolt line):

  • Gross length: 30 + 2 × 60 = 150 mm
  • A_gv = 150 × 10 = 1500 mm²
  • Net deduction: 2.5 holes × 22 × 10 = 550 mm² (2 full + 1 half)
  • A_nv = 1500 − 550 = 950 mm²

Tension plane (perpendicular, at the top bolt):

  • Gross length: 30 mm (edge to bolt center)
  • A_nt = (30 − 22/2) × 10 = 190 mm²

φR_n = 0.75 × (0.6 × 400 × 950 + 1.0 × 400 × 190) × 10⁻³ = 0.75 × (228000 + 76000) × 10⁻³ = 0.75 × 304 = 228 kN

This is less than bolt shear (323 kN) and less than tearout (342 kN), so block shear governs this connection. The fix: add more edge distance, or widen the bolt pattern to a two-line arrangement.

CalcSteel connection detail showing the bolt group and plate edges along which a block-shear failure block would tear out
Block shear rips a wedge of plate bounded by the bolt line and the free edge — the CalcSteel detail lays out exactly those distances.

When should you use slip-critical bolted connections?

AISC 360-22 Section J3.8 requires slip-critical connections in specific situations:

  1. Oversized or slotted holes — Slip into bearing would cause misalignment
  2. Connections subject to fatigue — Repeated slip causes fretting and crack initiation at bolt holes
  3. Connections with combined shear and tension on bolts — Where slip could cause progressive failure
  4. Seismic connections — Per AISC 341, certain seismic connections must be slip-critical

Slip resistance calculation

φR_n = φ × μ × D_u × h_f × T_b × n_s

Where:

  • φ = 1.0 (for service load check) or 0.85 (for strength-level check)
  • μ = mean slip coefficient: 0.30 (Class A, unpainted clean mill scale) or 0.50 (Class B, blast-cleaned)
  • D_u = 1.13 (ratio of mean installed bolt pretension to specified minimum)
  • h_f = filler factor (1.0 for no fillers)
  • T_b = minimum bolt pretension (from AISC Table J3.1)
  • n_s = number of slip planes

For M20 A325 bolt, Class A surface, single slip plane:

  • T_b = 142 kN (Table J3.1)
  • φR_n = 1.0 × 0.30 × 1.13 × 1.0 × 142 × 1 = 48.1 kN per bolt

Compare with bearing-type shear: 107.7 kN. Slip-critical capacity is less than half! This is why slip-critical connections require more bolts. But they prevent the slip that causes fatigue damage.

Class B surfaces (blast-cleaned) give μ = 0.50, which brings the slip capacity to 80.2 kN — much closer to bearing capacity. The cost of surface preparation pays off in fewer bolts.

Need the tightening torque that produces that pretension T_b on site? Our free bolt torque calculator converts preload to torque in seconds — no sign-up.

CalcSteel Bolt Torque Calculator
CalcSteel's free Bolt Torque Calculator — the exact calculation this article walks through, live in your browser, no signup.

How do you check bolts loaded in tension, and what is prying action?

Every check so far assumed the bolts carry shear. Hangers, the tension flange of a moment connection, and bracing gussets instead load bolts in tension along their axis, and there a second effect appears that has no equivalent in shear: prying action.

Bolt tensile strength (AISC J3.6)

φR_n = φ × F_nt × A_b

  • φ = 0.75
  • F_nt = nominal tensile stress = 620 MPa for A325, 780 MPa for A490
  • A_b = nominal bolt area = π d² / 4

For one M20 A325 bolt: φR_n = 0.75 × 620 × 314.2 × 10⁻³ = 146 kN. If the required tension per bolt were 110 kN, the bolt looks comfortable, 146 > 110. But that is only half the story.

Why prying action matters

When a thin flange or end plate flexes under the applied tension T, its edges bear against the connected part. That contact force, Q, levers back onto the bolt, so the bolt actually resists T + Q, not T alone. Prying can add 20 to 40 percent to the bolt force, and it has failed connections that passed a naive tension check.

Worked example: 2×M20 A325 hanger, 14 mm flange

Geometry: bolt line to stem face b = 45 mm, bolt line to flange edge a = 40 mm, tributary length per bolt p = 90 mm, hole d′ = 22 mm, F_u = 400 MPa. Required tension T = 110 kN per bolt.

  • b′ = b − d_b/2 = 45 − 10 = 35 mm
  • a′ = min(a, 1.25b) + d_b/2 = 40 + 10 = 50 mm
  • ρ = b′/a′ = 0.70; δ = 1 − d′/p = 1 − 22/90 = 0.756
  • β = (1/ρ)(B/T − 1) = (1/0.70)(146/110 − 1) = 0.47
  • β < 1, so α′ = (1/δ)[β/(1 − β)] = 1.0 (capped at 1.0)
  • Required flange thickness t_req = √[ 4 T b′ / (φ_b p F_u (1 + δα′)) ] = √[ 4 × 110×10³ × 35 / (0.90 × 90 × 400 × 1.756) ] = 16.5 mm

The 14 mm flange is thinner than the 16.5 mm required, so prying governs and the connection fails, even though the bolt tension check passed with a third to spare. The fixes: thicken the flange to at least 16.5 mm, shorten the gauge b, or add bolts so each carries less tension.

Free-body diagram of a T-stub hanger showing the applied tension T, bolt tension B and the prying force Q at the flange edges, with the required 16.5 mm flange versus the 14 mm provided
Prying makes each bolt resist T + Q: the 14 mm flange needs 16.5 mm, so the joint fails even though the bare bolt tension check passed.

How do you check bolts under combined shear and tension?

Diagonal braces, eccentric brackets and end-plate moment connections load a single bolt with shear and tension at once. AISC 360-22 Section J3.7 does not add the two utilisations; it lowers the available tensile stress in proportion to the shear present.

The interaction equation (AISC J3.7)

φR_n = φ × F′_nt × A_b, with F′_nt = 1.3 F_nt − (F_nt / (φ F_nv)) × f_rv ≤ F_nt

  • φ = 0.75
  • f_rv = required shear stress on the bolt = V_u / A_b
  • The reduced F′_nt is capped at the pure tension value F_nt

Worked example: M20 A325-N with 60 kN shear per bolt

  • f_rv = 60 000 / 314.2 = 191 MPa < φF_nv = 0.75 × 457 = 343 MPa, so shear alone is fine
  • F′_nt = 1.3 × 620 − (620 / (0.75 × 457)) × 191 = 806 − 346 = 460 MPa ≤ 620 MPa
  • Available tension per bolt: φR_n = 0.75 × 460 × 314.2 × 10⁻³ = 108 kN

The 60 kN of shear dropped each bolt's tensile capacity from 146 kN to 108 kN, a 26 percent cut. A required tension of 95 kN per bolt still passes (95 < 108), but that same bolt would have looked fine at 146 kN if you ignored the shear. Always evaluate F′_nt with the real shear demand, never the two limit states in isolation.

> CalcSteel tip: the connection engine applies J3.7 on every bolt, and when the joint is slip-critical it also scales the slip resistance by the factor k_sc for the tension present.

Bar chart comparing an M20 A325-N bolt's tensile capacity of 146 kN alone with 108 kN when 60 kN of shear is present, a 26 percent reduction
Combined shear and tension per AISC J3.7: 60 kN of shear cuts the M20 A325-N bolt's tensile capacity from 146 kN to 108 kN.

How do you lay out a bolt group for maximum efficiency?

Bolt layout follows specific AISC rules (J3.3-J3.5) and practical guidelines:

Minimum spacing

  • Center-to-center: 2⅔d (preferred 3d). For M20: minimum 53 mm, preferred 60 mm
  • Closer spacing makes bearing and tearout critical

Minimum edge distance

  • Standard holes: depends on bolt size and edge type (sheared vs rolled). For M20: 26 mm minimum (Table J3.4)
  • Preferred: 1.5d to 2d (30-40 mm for M20)

Maximum spacing and edge distance

  • Maximum spacing: min(24t, 305 mm) for painted members, min(14t, 178 mm) for unpainted
  • Maximum edge distance: 12t ≤ 150 mm
  • These limits prevent moisture entry and ensure load sharing

Practical layout rules

  1. Use standard gauges — W-shape flange gauges are tabulated in the AISC Manual (Table 1-7A). Using standard gauges means standard connection angles and fewer fabrication errors.
  2. Two vertical rows are better than one — Doubles block shear capacity and reduces eccentricity
  3. Stagger bolts when possible — Staggered patterns improve net section efficiency
  4. Keep bolt count manageable — More than 6-8 bolts in a line causes unequal load distribution. Group into two or more lines.
  5. Match plate thickness to bolt size — Rule of thumb: plate thickness ≥ bolt diameter for efficient bearing. Thinner plates waste bolt capacity.

The same layout discipline carries over to column base plate design, where anchor-rod groups replace through-bolts but the spacing and edge-distance logic is identical.

Key bolt detailing numbers: minimum spacing of 3d, minimum edge distance of 1.5d and 2 mm standard hole clearance
Minimum spacing (3d), minimum edge distance (1.5d) and standard 2 mm hole clearance govern every bolt-group layout.

How does CalcSteel design bolted connections automatically?

Manual bolt connection design requires checking five or more failure modes at every bolt location, for every load combination. CalcSteel automates this:

What the connection engine checks

  1. Bolt shear — Single or double shear, threads included or excluded, per bolt group
  2. Bearing and tearout — At every bolt, considering actual edge and spacing distances
  3. Block shear — All possible failure paths, including L-shaped and U-shaped patterns
  4. Net section rupture — Accounting for staggered holes via the s²/4g rule
  5. Combined shear and tension — The AISC elliptical interaction equation
  6. Slip resistance — When the connection is flagged as slip-critical

How the optimizer works

Given the demand forces at a node, the connection engine:

  • Selects bolt grade and diameter (starting from M16 A325-N)
  • Tries bolt patterns (single line, double line, staggered) with standard gauges
  • Checks all failure modes for the lightest combination
  • Reports the governing mode and the utilization ratio

The result is a fully code-compliant connection that you can verify against the hand calculation shown above. Every intermediate value — clear distance, net area, slip coefficient — is visible in the connection detail report.

When to intervene

The optimizer handles standard cases well, but some situations require engineering judgment:

  • Connections with eccentricity (bolt groups loaded off-center)
  • Moment connections with bolt groups in tension and compression
  • Connections at beam copes where multiple failure modes interact
  • Mixed connections with both bolts and welds, where the weld leg must be sized per fillet weld strength

In these cases, override the auto-design and verify each limit state manually using the detailed output.

3D view of a bolted steel connection modelled and auto-designed in the CalcSteel connection editor
CalcSteel designs and renders the bolted connection in 3D, reporting the governing limit state.

Try CalcSteel for free

Model, analyze and design steel structures in your browser. No install, no signup.