Tecnometal, cold-formed sections (Italy) · Angle Section
Angle sections (L shapes) are used for bracing, connections, lintels, and built-up members. Available in equal and unequal leg configurations.
The L 40x20x2 steel profile weighs 0.9 kg/m (0.62 lb/ft), has a depth of 40 mm (1.57 in), flange width 20 mm (0.79 in). Cross-sectional area: 113.425 mm². Moment of inertia Ix = 1.915 cm⁴, Iy = 0.345 cm⁴.
| Property | Metric | Imperial |
|---|---|---|
| Depth (h) | 40 mm | 1.57 in |
| Width (b) | 20 mm | 0.79 in |
| Thickness (t) | 2 mm | 0.08 in |
| Fillet radius (r) | 2 mm | 0.08 in |
| Weight | 0.9 kg/m | 0.62 lb/ft |
| Property | Metric | Imperial |
|---|---|---|
| Area (A) | 113.42 mm² | 0.176 in² |
| Moment of inertia (Ix) | 1.91 cm⁴ | 0.05 in⁴ |
| Moment of inertia (Iy) | 0.34 cm⁴ | 0.01 in⁴ |
| Elastic section modulus (Sx) | 0.75 cm³ | 0.046 in³ |
| Elastic section modulus (Sy) | 0.22 cm³ | 0.013 in³ |
| Plastic section modulus (Zx) | 1.12 cm³ | 0.068 in³ |
| Plastic section modulus (Zy) | 0.33 cm³ | 0.020 in³ |
| Radius of gyration (rx) | 1.3 cm | 0.512 in |
| Radius of gyration (ry) | 0.55 cm | 0.217 in |
15.0 kN·m
15.0 kN
4406.91 mm
L/1