C 100x75x15x2 IAS Weight & Dimensions · 4.2 kg/m | Free Calculator

C 100x75x15x2 IAS · Weight & Dimensions

IAS, cold-formed sections · Cold-formed Lipped Channel

Cold-formed lipped channels (C shapes) are lightweight profiles commonly used as purlins, girts, and light framing members. The stiffening lips increase local buckling resistance. Designed per AISI S100 and NBR 14762.

Also known as: Montén de 4 pulgadas (México) · PFC 100x75x15x2 (UK / Australia)

The C 100x75x15x2 steel profile weighs 4.2 kg/m (2.82 lb/ft), has a depth of 100 mm (3.94 in), flange width 75 mm (2.95 in). Cross-sectional area: 533.684 mm². Moment of inertia Ix = 93.248 cm⁴, Iy = 40.243 cm⁴.

h=100b=75t=2lip=15
Cross-section (not to scale)

Dimensions

PropertyMetricImperial
Depth (h)100 mm3.94 in
Width (b)75 mm2.95 in
Thickness (t)2 mm0.08 in
Lip15 mm0.59 in
Fillet radius (r)2 mm0.08 in
Weight4.2 kg/m2.82 lb/ft

Section Properties

PropertyMetricImperial
Area (A)533.68 mm²0.827 in²
Moment of inertia (Ix)93.25 cm⁴2.24 in⁴
Moment of inertia (Iy)40.24 cm⁴0.97 in⁴
Elastic section modulus (Sx)18.65 cm³1.138 in³
Elastic section modulus (Sy)8.55 cm³0.522 in³
Plastic section modulus (Zx)21.46 cm³1.310 in³
Plastic section modulus (Zy)11.78 cm³0.719 in³
Radius of gyration (rx)4.18 cm1.646 in
Radius of gyration (ry)2.75 cm1.081 in

Beam Calculator— C 100x75x15x2

drag to orbit
mfixed @ 0mfixed @ 6m→kN/m

Results — C 100x75x15x2

Mmax

15.0 kN·m

Vmax

15.0 kN

δmax

90.48 mm

L/66

R115.0 kN| 15.0 kN·mR215.0 kN| -15.0 kN·m
Standard:

Lose the fear of working in 3D

No installation, right in the browser — start now

Try the 3D Editor