I 450x250x8x16 Cintac Weight & Dimensions · 89.0 kg/m | Free Calculator

I 450x250x8x16 Cintac · Weight & Dimensions

Cintac, welded sections · Wide Flange (I-beam)

Wide flange beams (W shapes / I-beams) are the most common structural steel profile used in building construction. They are used for beams, columns, and girders in steel-framed buildings and bridges. Designed per AISC 360, Eurocode 3, and NBR 8800.

Also known as: I 450x250x8x16 (México) · Doble T I 450x250x8x16 (Argentina / LATAM) · UB 450 (UK / Australia)

The I 450x250x8x16 steel profile weighs 89.0 kg/m (59.82 lb/ft), has a depth of 450 mm (17.72 in), flange width 250 mm (9.84 in). Cross-sectional area: 11,344 mm². Moment of inertia Ix = 42,557.242 cm⁴, Iy = 4,168.45 cm⁴.

h=450b=250tw=8tf=16
Cross-section (not to scale)

Dimensions

PropertyMetricImperial
Depth (h)450 mm17.72 in
Width (b)250 mm9.84 in
Web thickness (tw)8 mm0.31 in
Flange thickness (tf)16 mm0.63 in
Weight89.0 kg/m59.82 lb/ft

Section Properties

PropertyMetricImperial
Area (A)11,344 mm²17.583 in²
Moment of inertia (Ix)42,557.24 cm⁴1022.44 in⁴
Moment of inertia (Iy)4,168.45 cm⁴100.15 in⁴
Elastic section modulus (Sx)1,891.43 cm³115.423 in³
Elastic section modulus (Sy)333.48 cm³20.350 in³
Plastic section modulus (Zx)2,085.45 cm³127.262 in³
Plastic section modulus (Zy)506.69 cm³30.920 in³
Radius of gyration (rx)19.37 cm7.626 in
Radius of gyration (ry)6.06 cm2.387 in

Beam Calculator— I 450x250x8x16

drag to orbit
mfixed @ 0mfixed @ 6m→kN/m

Results — I 450x250x8x16

Mmax

15.0 kN·m

Vmax

15.0 kN

δmax

0.20 mm

L/30263

R115.0 kN| 15.0 kN·mR215.0 kN| -15.0 kN·m
Standard:

Lose the fear of working in 3D

No installation, right in the browser — start now

Try the 3D Editor