Cintac, welded sections · Wide Flange (I-beam)
Wide flange beams (W shapes / I-beams) are the most common structural steel profile used in building construction. They are used for beams, columns, and girders in steel-framed buildings and bridges. Designed per AISC 360, Eurocode 3, and NBR 8800.
The I 250x200x6x14 steel profile weighs 54.4 kg/m (36.56 lb/ft), has a depth of 250 mm (9.84 in), flange width 200 mm (7.87 in). Cross-sectional area: 6,932 mm². Moment of inertia Ix = 8,353.639 cm⁴, Iy = 1,867.066 cm⁴.
| Property | Metric | Imperial |
|---|---|---|
| Depth (h) | 250 mm | 9.84 in |
| Width (b) | 200 mm | 7.87 in |
| Web thickness (tw) | 6 mm | 0.24 in |
| Flange thickness (tf) | 14 mm | 0.55 in |
| Weight | 54.4 kg/m | 36.56 lb/ft |
| Property | Metric | Imperial |
|---|---|---|
| Area (A) | 6,932 mm² | 10.745 in² |
| Moment of inertia (Ix) | 8,353.64 cm⁴ | 200.70 in⁴ |
| Moment of inertia (Iy) | 1,867.07 cm⁴ | 44.86 in⁴ |
| Elastic section modulus (Sx) | 668.29 cm³ | 40.782 in³ |
| Elastic section modulus (Sy) | 186.71 cm³ | 11.394 in³ |
| Plastic section modulus (Zx) | 734.73 cm³ | 44.836 in³ |
| Plastic section modulus (Zy) | 282 cm³ | 17.209 in³ |
| Radius of gyration (rx) | 10.98 cm | 4.322 in |
| Radius of gyration (ry) | 5.19 cm | 2.043 in |
15.0 kN·m
15.0 kN
1.01 mm
L/5940