I 250x200x4x12 Cintac Weight & Dimensions · 44.8 kg/m | Free Calculator

I 250x200x4x12 Cintac · Weight & Dimensions

Cintac, welded sections · Wide Flange (I-beam)

Wide flange beams (W shapes / I-beams) are the most common structural steel profile used in building construction. They are used for beams, columns, and girders in steel-framed buildings and bridges. Designed per AISC 360, Eurocode 3, and NBR 8800.

Also known as: I 250x200x4x12 (México) · Doble T I 250x200x4x12 (Argentina / LATAM) · UB 250 (UK / Australia)

The I 250x200x4x12 steel profile weighs 44.8 kg/m (30.07 lb/ft), has a depth of 250 mm (9.84 in), flange width 200 mm (7.87 in). Cross-sectional area: 5,704 mm². Moment of inertia Ix = 7,187.813 cm⁴, Iy = 1,600.121 cm⁴.

h=250b=200tw=4tf=12
Cross-section (not to scale)

Dimensions

PropertyMetricImperial
Depth (h)250 mm9.84 in
Width (b)200 mm7.87 in
Web thickness (tw)4 mm0.16 in
Flange thickness (tf)12 mm0.47 in
Weight44.8 kg/m30.07 lb/ft

Section Properties

PropertyMetricImperial
Area (A)5,704 mm²8.841 in²
Moment of inertia (Ix)7,187.81 cm⁴172.69 in⁴
Moment of inertia (Iy)1,600.12 cm⁴38.44 in⁴
Elastic section modulus (Sx)575.03 cm³35.090 in³
Elastic section modulus (Sy)160.01 cm³9.765 in³
Plastic section modulus (Zx)622.28 cm³37.974 in³
Plastic section modulus (Zy)240.9 cm³14.701 in³
Radius of gyration (rx)11.23 cm4.420 in
Radius of gyration (ry)5.3 cm2.085 in

Beam Calculator— I 250x200x4x12

drag to orbit
mfixed @ 0mfixed @ 6m→kN/m

Results — I 250x200x4x12

Mmax

15.0 kN·m

Vmax

15.0 kN

δmax

1.17 mm

L/5111

R115.0 kN| 15.0 kN·mR215.0 kN| -15.0 kN·m
Standard:

Lose the fear of working in 3D

No installation, right in the browser — start now

Try the 3D Editor