Cintac, welded sections · Wide Flange (I-beam)
Wide flange beams (W shapes / I-beams) are the most common structural steel profile used in building construction. They are used for beams, columns, and girders in steel-framed buildings and bridges. Designed per AISC 360, Eurocode 3, and NBR 8800.
The I 250x100x4x5 steel profile weighs 15.4 kg/m (10.34 lb/ft), has a depth of 250 mm (9.84 in), flange width 100 mm (3.94 in). Cross-sectional area: 1,960 mm². Moment of inertia Ix = 1,961.633 cm⁴, Iy = 83.461 cm⁴.
| Property | Metric | Imperial |
|---|---|---|
| Depth (h) | 250 mm | 9.84 in |
| Width (b) | 100 mm | 3.94 in |
| Web thickness (tw) | 4 mm | 0.16 in |
| Flange thickness (tf) | 5 mm | 0.20 in |
| Weight | 15.4 kg/m | 10.34 lb/ft |
| Property | Metric | Imperial |
|---|---|---|
| Area (A) | 1,960 mm² | 3.038 in² |
| Moment of inertia (Ix) | 1,961.63 cm⁴ | 47.13 in⁴ |
| Moment of inertia (Iy) | 83.46 cm⁴ | 2.01 in⁴ |
| Elastic section modulus (Sx) | 156.93 cm³ | 9.577 in³ |
| Elastic section modulus (Sy) | 16.69 cm³ | 1.019 in³ |
| Plastic section modulus (Zx) | 180.1 cm³ | 10.990 in³ |
| Plastic section modulus (Zy) | 25.96 cm³ | 1.584 in³ |
| Radius of gyration (rx) | 10 cm | 3.939 in |
| Radius of gyration (ry) | 2.06 cm | 0.812 in |
15.0 kN·m
15.0 kN
4.30 mm
L/1395